Glass fence panel layout calculator

Fence / Layout

Fit supplied glass panel widths and gap bounds to a straight run, including known gate clearances and spigot positions.

Enter your inputs

A worked project example is loaded and calculated automatically. Replace the values with your project inputs.

Input notes

Use actual panel widths available from your supplier. The standard search checks equal widths or two adjacent supplied sizes, choosing the gap nearest above your minimum and then fewer panels. It does not search arbitrary combinations of three or more sizes; enter an actual sequence for that case. All examples are arithmetic inputs, not standard-size availability or code limits. End gaps use the same value as internal regular gaps.

Custom mode computes equal dimensions for a fabricator at the exact Minimum gap; Custom panel count excludes a separately specified hinge panel. A gate is internal, between panels: enter its actual panel width, hinge/latch clearances, and the panel number immediately before it. Fixed hinge panel width 0 means none; a positive width inserts one on the chosen hinge side. Spigot set-in and maximum centers must come from your selected system. This does not approve glass, supports, clearances or an installation.

in
Use the selected run length unit. Panel widths, gaps, and support positions use inches.
Choose the option that matches your project.
Choose the option that matches your project.
Enter actual panel widths in inches, separated by commas or newlines. Known-sequence mode preserves their order. Standard search accepts up to 32 distinct sizes.
in
Enter minimum gap in inches.
in
Enter maximum gap in inches.
Choose the option that matches your project.
in
Enter spigot set-in in inches.
in
Enter maximum spigot centers in inches.
Choose the option that matches your project.

About this calculator

This layout fits the supplied panel widths to one straight run while honoring the entered gap bounds, end conditions, gate details, and support set-in.

Steps

  1. Run length

    Use the selected run length unit. Panel widths, gaps, and support positions use inches.

  2. Run length unit

    Choose the option that matches your project.

  3. Panel mode

    Choose the option that matches your project.

  4. Panel widths

    Enter actual panel widths in inches, separated by commas or newlines. Known-sequence mode preserves their order. Standard search accepts up to 32 distinct sizes.

  5. Custom panel count (available in another mode)

    Use a whole number.

  6. Minimum gap

    Enter minimum gap in inches.

  7. Maximum gap

    Enter maximum gap in inches.

  8. End gaps

    Choose the option that matches your project.

  9. Spigot set-in

    Enter spigot set-in in inches.

  10. Maximum spigot centers

    Enter maximum spigot centers in inches.

  11. Internal gate

    Choose the option that matches your project.

  12. Gate panel width (available in another mode)

    Enter gate panel width in inches.

  13. Hinge gap (available in another mode)

    Enter hinge gap in inches.

  14. Latch gap (available in another mode)

    Enter latch gap in inches.

  15. Gate after panel (available in another mode)

    Use a whole number.

  16. Hinge side (available in another mode)

    Choose the option that matches your project.

  17. Fixed hinge panel width (available in another mode)

    Enter fixed hinge panel width in inches.

Formula

Regular gaps = fixed panel count − 1 + selected end gaps − one gap replaced by an internal gate. Gap = (run − gate/clearances − panel widths) ÷ regular gaps. Standard modes search supplied equal widths or two adjacent supplied sizes, minimizing gap above the minimum, then panel count. Custom mode divides remaining width equally at the exact entered minimum gap. Spigot center intervals = ceil((panel width − 2 × set-in) ÷ entered maximum centers).

Notation: ceil rounds up to the next whole number.

Interpret the result

The displayed panel widths and gaps are a geometric specification for review. They do not approve glass, hardware, supports, pool barriers, installation, or arbitrary cutting.

Worked example

Four 48-in panels and one 42-in panel use 4 × 48 + 42 = 234 in. The 240-in run leaves 6 in across four regular gaps, so each gap is 6 ÷ 4 = 1.5 in, within the entered 1-to-2-in range.

Example result: 5 panels; 1.5 in gaps

Example inputs
Run length
240 in
Run length unit
Inches
Panel mode
Mixed adjacent standard sizes
Panel widths
42,48
Minimum gap
1 in
Maximum gap
2 in
End gaps
No end gaps
Spigot set-in
6 in
Maximum spigot centers
36 in
Internal gate
No gate

FAQs

Can it find every possible panel combination?

No. Standard search is limited to the supplied equal or adjacent sizes; use known sequence for a specific arrangement.

What do the layout marks refer to?

Use the stated origin, centerline or face reference, and units shown with the result. Display rounding may differ from the internal coordinates.

Does this approve the selected dimensions or product?

No. It lays out the dimensions you enter and does not establish structural capacity, product cutting permission, or installation compliance.

Additional examples and limits

Glass layout examples and constraints

For a 240 in run, supplied 42/48 in panels, no end gaps, Minimum gap 1 in and Maximum gap 2 in: four 48 in panels and one 42 in panel total 234 in. Four equal gaps use the remaining 6 in, or 1.5 in each. At 6 in spigot set-in and 36 in entered maximum centers, each panel has two supports. The first pair is at 6 and 42 in, and the last panel ends at 240 in.

Known-sequence gate example: three 48 in panels, a 36 in gate, 0.5 in hinge and latch clearances, no end gaps, and a 183 in total run leave one regular 2 in gap. The gate after panel 1 runs from 48.5 to 84.5 in. The other panels start at 85 and 135 in. Gate glass and clearances are separate from the regular gap; the fixed panels include any explicitly inserted hinge panel.

Boundary: one 48 in panel in a 48 in run has no regular gap. Custom mode with 148 in total, 2 panels, no end gaps and an exact 4 in gap gives two 72 in panel specifications. These are not instructions to trim purchased glass. No fit, consumed width, negative gaps, nonpositive dimensions, more than 100 panels or more than 1,000 support coordinates is accepted. The mixed search filters panels too short for both support set-ins before comparing candidates.

The tool supports supplied equal or adjacent panel sizes, a known sequence, custom equal dimensions, an internal gate, and support marks. Its search is limited to the entered sizes and the two entered gap bounds; it does not search every possible combination. Gates at a run end, multiple gates, curved/angled runs, custom hardware, loads, pool requirements, glass type and compliance are outside this straight-run model.