Fence gate materials and cut list calculator

Fence / Quantity

Estimate wood gate frame, diagonal blanks, vertical infill, selected hardware quantities and feasible lumber cuts from an explicitly entered single- or double-leaf recipe.

Enter your inputs

A worked project example is loaded and calculated automatically. Replace the values with your project inputs.

1. Gate opening and leaves

gates
Use a whole number.
Choose the option that matches your project.
in
Enter clear opening width in inches.
in
Enter finished leaf height in inches.
in
Enter side clearance at each jamb in inches.
in
Enter actual stile width in inches.
in
Enter actual horizontal rail depth in inches.

2. User-entered frame recipe

rails
Use a whole number.
braces
Use a whole number.

3. Infill and faces

Choose the option that matches your project.
in
Enter actual infill board width in inches.
in
Enter maximum equal infill gap, including edge gaps in inches.
in
Enter infill top clearance in inches.
in
Enter infill bottom clearance in inches.
faces
Use a whole number.

4. User-entered hardware

each
Use a whole number.
each
Use a whole number.

5. Compatible stock and cutting

Each line: material group (FRAME or INFILL), stock length (in), quantity or *, new or offcut. Separate columns with commas. * means unlimited new stock; offcuts need finite whole quantities.
in
Enter saw kerf in inches.
in
Enter left-end trim including its kerf in inches.
in
Enter right-end trim including its kerf in inches.
in
Enter minimum retained remnant in inches.

About this calculator

Gate takeoff applies a user-declared single- or double-leaf recipe to clear opening, frame dimensions, infill, hardware counts, and compatible lumber stock.

Steps

  1. Identical gate assemblies

    Use a whole number.

  2. Leaves per assembly

    Choose the option that matches your project.

  3. Clear opening width

    Enter clear opening width in inches.

  4. Finished leaf height

    Enter finished leaf height in inches.

  5. Side clearance at each jamb

    Enter side clearance at each jamb in inches.

  6. Center gap between leaves (available in another mode)

    Enter center gap between leaves in inches.

  7. Actual stile width

    Enter actual stile width in inches.

  8. Actual horizontal rail depth

    Enter actual horizontal rail depth in inches.

  9. User-selected rails per leaf

    Use a whole number.

  10. User-selected diagonal blanks per leaf

    Use a whole number.

  11. Vertical picket infill

    Choose the option that matches your project.

  12. Actual infill board width

    Enter actual infill board width in inches.

  13. Maximum equal infill gap, including edge gaps

    Enter maximum equal infill gap, including edge gaps in inches.

  14. Infill top clearance

    Enter infill top clearance in inches.

  15. Infill bottom clearance

    Enter infill bottom clearance in inches.

  16. Infilled faces

    Use a whole number.

  17. Entered hinges per leaf

    Use a whole number.

  18. Entered latch sets per assembly

    Use a whole number.

  19. Entered drop rods per double-leaf assembly (available in another mode)

    Use a whole number.

  20. Compatible lumber stock and offcuts

    Each line: material group (FRAME or INFILL), stock length (in), quantity or *, new or offcut. Separate columns with commas. * means unlimited new stock; offcuts need finite whole quantities.

  21. Saw kerf

    Enter saw kerf in inches.

  22. Left-end trim including its kerf

    Enter left-end trim including its kerf in inches.

  23. Right-end trim including its kerf

    Enter right-end trim including its kerf in inches.

  24. Minimum retained remnant

    Enter minimum retained remnant in inches.

Formula

Leaf width = (clear opening − 2 × side clearance − (leaf count−1) × center gap) ÷ leaf count. Stiles = 2 per leaf at finished height. Rails = entered rails per leaf at leaf width − 2 × stile width. The straight diagonal blank spans the clear frame rectangle: hypot(leaf width−2×stile width, leaf height−2×rail depth); entered braces per leaf control count. Vertical infill uses full-width pickets with equal side/inter-board gaps: choose the fewest boards fitting the clear width while keeping each equal gap at or below the entered maximum; infeasible no-rip patterns reject. Hardware counts use the entered recipe. A shared bounded cut allocator fits those known lengths to grouped stock with full kerf, trims and finite offcuts. No member, brace, connection or code requirement is selected.

Notation: hypot gives the diagonal length from two perpendicular sides.

Interpret the result

The listed quantities and cuts follow that recipe. They do not choose a brace, connection, hinge rating, or code requirement.

Worked example

Two gate assemblies × one leaf each = 2 leaves. With 2 entered hinges per leaf, 2 × 2 = 4 hinges.

Example result: 2 gates; 2 leaves; 4 hinges

Example inputs
Identical gate assemblies
2 gates
Leaves per assembly
Single leaf
Clear opening width
120 in
Finished leaf height
72 in
Side clearance at each jamb
1 in
Actual stile width
3.5 in
Actual horizontal rail depth
3.5 in
User-selected rails per leaf
3 rails
User-selected diagonal blanks per leaf
1 braces
Vertical picket infill
Vertical pickets
Actual infill board width
5.5 in
Maximum equal infill gap, including edge gaps
0.25 in
Infill top clearance
1 in
Infill bottom clearance
1 in
Infilled faces
1 faces
Entered hinges per leaf
2 each
Entered latch sets per assembly
1 each
Compatible lumber stock and offcuts
FRAME,144,*,new INFILL,96,*,new
Saw kerf
0.125 in
Left-end trim including its kerf
0 in
Right-end trim including its kerf
0 in
Minimum retained remnant
6 in

FAQs

Does the calculator decide rails and braces per leaf?

No. Rail and brace counts are part of the gate recipe you enter.

Does this include a purchase allowance?

Only allowances shown in the inputs and formula are applied. If no waste, reserve, or package field is listed, the result does not infer one.

Does this make a complete construction or product plan?

No. It calculates the listed quantities from known inputs; it does not select structural dimensions, product compatibility, or code requirements.