Fence gate materials and cut list calculator
Estimate wood gate frame, diagonal blanks, vertical infill, selected hardware quantities and feasible lumber cuts from an explicitly entered single- or double-leaf recipe.
About this calculator
Gate takeoff applies a user-declared single- or double-leaf recipe to clear opening, frame dimensions, infill, hardware counts, and compatible lumber stock.
Steps
- Identical gate assembliesIdentical gate assemblies (available in another mode)
Use a whole number.
- Leaves per assemblyLeaves per assembly (available in another mode)
Choose the option that matches your project.
- Clear opening widthClear opening width (available in another mode)
Enter clear opening width in inches.
- Finished leaf heightFinished leaf height (available in another mode)
Enter finished leaf height in inches.
- Side clearance at each jambSide clearance at each jamb (available in another mode)
Enter side clearance at each jamb in inches.
- Center gap between leavesCenter gap between leaves (available in another mode)
Enter center gap between leaves in inches.
- Actual stile widthActual stile width (available in another mode)
Enter actual stile width in inches.
- Actual horizontal rail depthActual horizontal rail depth (available in another mode)
Enter actual horizontal rail depth in inches.
- User-selected rails per leafUser-selected rails per leaf (available in another mode)
Use a whole number.
- User-selected diagonal blanks per leafUser-selected diagonal blanks per leaf (available in another mode)
Use a whole number.
- Vertical picket infillVertical picket infill (available in another mode)
Choose the option that matches your project.
- Actual infill board widthActual infill board width (available in another mode)
Enter actual infill board width in inches.
- Maximum equal infill gap, including edge gapsMaximum equal infill gap, including edge gaps (available in another mode)
Enter maximum equal infill gap, including edge gaps in inches.
- Infill top clearanceInfill top clearance (available in another mode)
Enter infill top clearance in inches.
- Infill bottom clearanceInfill bottom clearance (available in another mode)
Enter infill bottom clearance in inches.
- Infilled facesInfilled faces (available in another mode)
Use a whole number.
- Entered hinges per leafEntered hinges per leaf (available in another mode)
Use a whole number.
- Entered latch sets per assemblyEntered latch sets per assembly (available in another mode)
Use a whole number.
- Entered drop rods per double-leaf assemblyEntered drop rods per double-leaf assembly (available in another mode)
Use a whole number.
- Compatible lumber stock and offcutsCompatible lumber stock and offcuts (available in another mode)
Each line: material group (FRAME or INFILL), stock length (in), quantity or *, new or offcut. Separate columns with commas. * means unlimited new stock; offcuts need finite whole quantities.
- Saw kerfSaw kerf (available in another mode)
Enter saw kerf in inches.
- Left-end trim including its kerfLeft-end trim including its kerf (available in another mode)
Enter left-end trim including its kerf in inches.
- Right-end trim including its kerfRight-end trim including its kerf (available in another mode)
Enter right-end trim including its kerf in inches.
- Minimum retained remnantMinimum retained remnant (available in another mode)
Enter minimum retained remnant in inches.
Formula
Leaf width = (clear opening − 2 × side clearance − (leaf count−1) × center gap) ÷ leaf count. Stiles = 2 per leaf at finished height. Rails = entered rails per leaf at leaf width − 2 × stile width. The straight diagonal blank spans the clear frame rectangle: hypot(leaf width−2×stile width, leaf height−2×rail depth); entered braces per leaf control count. Vertical infill uses full-width pickets with equal side/inter-board gaps: choose the fewest boards fitting the clear width while keeping each equal gap at or below the entered maximum; infeasible no-rip patterns reject. Hardware counts use the entered recipe. A shared bounded cut allocator fits those known lengths to grouped stock with full kerf, trims and finite offcuts. No member, brace, connection or code requirement is selected.
Notation: hypot gives the diagonal length from two perpendicular sides.
Interpret the result
The listed quantities and cuts follow that recipe. They do not choose a brace, connection, hinge rating, or code requirement.
Worked example
Two gate assemblies × one leaf each = 2 leaves. With 2 entered hinges per leaf, 2 × 2 = 4 hinges.
Example result: 2 gates; 2 leaves; 4 hinges
Example inputs
- Identical gate assemblies
- 2 gates
- Leaves per assembly
- Single leaf
- Clear opening width
- 120 in
- Finished leaf height
- 72 in
- Side clearance at each jamb
- 1 in
- Actual stile width
- 3.5 in
- Actual horizontal rail depth
- 3.5 in
- User-selected rails per leaf
- 3 rails
- User-selected diagonal blanks per leaf
- 1 braces
- Vertical picket infill
- Vertical pickets
- Actual infill board width
- 5.5 in
- Maximum equal infill gap, including edge gaps
- 0.25 in
- Infill top clearance
- 1 in
- Infill bottom clearance
- 1 in
- Infilled faces
- 1 faces
- Entered hinges per leaf
- 2 each
- Entered latch sets per assembly
- 1 each
- Compatible lumber stock and offcuts
- FRAME,144,*,new INFILL,96,*,new
- Saw kerf
- 0.125 in
- Left-end trim including its kerf
- 0 in
- Right-end trim including its kerf
- 0 in
- Minimum retained remnant
- 6 in
FAQs
Does the calculator decide rails and braces per leaf?
No. Rail and brace counts are part of the gate recipe you enter.
Does this include a purchase allowance?
Only allowances shown in the inputs and formula are applied. If no waste, reserve, or package field is listed, the result does not infer one.
Does this make a complete construction or product plan?
No. It calculates the listed quantities from known inputs; it does not select structural dimensions, product compatibility, or code requirements.
