Fence panel and layout calculator

Fence / Layout

Fit panels between posts using actual post widths, end-post placement and equal or cut-end panels. Rail footage covers clear openings only.

Enter your inputs

A worked project example is loaded and calculated automatically. Replace the values with your project inputs.

Choose the option that matches your project.
ft
Enter fence run length in feet.
ft
Enter target panel width in feet.
in
Enter actual post width in inches.
Choose the option that matches your project.
rails
Use a whole number.
posts
Use a whole number.
Limits and notes

Measure total length between the outside faces of the end posts, or to the panel boundary at an end with no post. Actual post width is measured along the run. Target panel width is the maximum clear opening; no connection clearance is added. One-end mode places its post at the start. Corner posts are extra purchase quantities outside this straight run and do not change its geometry. Rail footage spans clear openings; joints, brackets, gates, slopes and rails running past posts are excluded.

Target width is a strict maximum. If full panels leave no positive last panel, choose an even fit or cuts at both ends. A single panel uses the remaining clear width.

About this calculator

Panel layout fits clear openings into a measured run after accounting for actual post widths and the selected end-post arrangement.

Steps

  1. Panel fit

    Choose the option that matches your project.

  2. Fence run length

    Enter fence run length in feet.

  3. Target panel width

    Enter target panel width in feet.

  4. Actual post width

    Enter actual post width in inches.

  5. End posts

    Choose the option that matches your project.

  6. Rails per section

    Use a whole number.

  7. Corner posts

    Use a whole number.

Formula

Use inches: panels = max(1, ceil((run length − (end posts − 1) × post width) ÷ (target panel width + post width))); posts = panels − 1 + end posts; net panel length = run length − posts × post width. Divide net length equally, cut the last panel, or share the end cuts. Panel count uses exact decimal ratios after numeric validation; every panel must be positive and no wider than the target.

Notation: ceil rounds up to the next whole number; max selects the largest value.

Interpret the result

The panel count and cut widths follow the entered maximum panel width. Rail footage covers clear openings and excludes unentered joint or connection allowances.

Worked example

The 100-ft run is 1,200 in. With two end posts at 3.5 in each, 1,193 in remain; at an 8-ft (96-in) maximum panel width, the model needs ceil(1,193 ÷ 99.5) = 13 panels.

Example result: 13 panels

Example inputs
Panel fit
Fit panels evenly
Fence run length
100 ft
Target panel width
8 ft
Actual post width
3.5 in
End posts
Post at each end
Rails per section
2 rails
Corner posts
0 posts

FAQs

When do end-post counts affect the panel fit?

The selected end-post mode determines how many actual post widths are deducted from the run.

What do the layout marks refer to?

Use the stated origin, centerline or face reference, and units shown with the result. Display rounding may differ from the internal coordinates.

Does this approve the selected dimensions or product?

No. It lays out the dimensions you enter and does not establish structural capacity, product cutting permission, or installation compliance.

Additional examples and limits

Panel width after post deductions

A 24-ft overall run, 8-ft maximum panel width and four 3.5-in posts leaves 288 − 4 × 3.5 = 274 in for three panels. Fit evenly: 91.333 in each. Cut the last: 96, 96 and 82 in. Cut both ends: 89, 96 and 89 in. Two rails per opening give six rail pieces and 45.667 linear ft before waste or connection allowances.

With a post only at the start, three posts leave 277.5 in, or 92.5 in per equal panel. No end posts leaves two internal posts and 93.667 in per panel. A 202.5-in run fits two 96-in panels and three 3.5-in posts exactly; adding 1/16 in requires a third panel under the entered maximum. A single-panel run uses the remaining clear width in every mode. These are geometric examples; post sizes, connection clearances and permitted panel cuts must come from the selected product and project plan.