Deck support grid calculator
Count supports from known bearer lines, a centerline grid, or an outside deck outline with actual member widths and set-ins.
About this calculator
For known bearer lines, the grid multiplies their count by the support positions required along each line at the entered spacing.
Steps
- Support inputSupport input (available in another mode)
Choose the option that matches your project.
- Deck lengthDeck length (available in another mode)
Enter deck length in feet.
- Bearer linesBearer lines (available in another mode)
Use a whole number.
- Support spacingSupport spacing (available in another mode)
Enter support spacing in feet.
- Deck widthDeck width (available in another mode)
Enter deck width in feet.
- Maximum cross-deck spacingMaximum cross-deck spacing (available in another mode)
Enter maximum cross-deck spacing in feet.
- Actual member thicknessActual member thickness (available in another mode)
Enter actual member thickness in inches.
- Inner set-inInner set-in (available in another mode)
Enter inner set-in in inches.
- Outer set-inOuter set-in (available in another mode)
Enter outer set-in in inches.
- Maximum bearer centersMaximum bearer centers (available in another mode)
Enter maximum bearer centers in feet.
- Bearer membersBearer members (available in another mode)
Choose the option that matches your project.
- Bearing boundaryBearing boundary (available in another mode)
Choose the option that matches your project.
- Actual ledger thicknessActual ledger thickness (available in another mode)
Enter actual ledger thickness in inches.
- Actual support widthActual support width (available in another mode)
Enter actual support width in inches.
- Support end set-inSupport end set-in (available in another mode)
Enter support end set-in in inches.
- Support centers along bearerSupport centers along bearer (available in another mode)
Enter support centers along bearer in feet.
Formula
known lines: bearers × (ceil(length ÷ support spacing) + 1). Centerline grid: equally divided maximum-spacing intervals on both axes. Outside outline (convert deck ft to in first): length center span in inches = deck length in inches − 2 × support set-in in inches − support width in inches; cross-deck centers use actual widths and set-ins in inches. Every pair of center marks is one support.
Notation: ceil rounds up to the next whole number.
Interpret the result
Each crossing of a bearer line and a support mark is counted once. The grid is a geometric takeoff, not foundation sizing.
Worked example
Three bearer lines with 16-ft runs and 4-ft maximum spacing use ceil(16 ÷ 4) + 1 = 5 supports each. 3 × 5 = 15 supports.
Example result: 15 supports
Example inputs
- Support input
- Known bearer line count
- Deck length
- 16 ft
- Bearer lines
- 3 lines
- Support spacing
- 4 ft
FAQs
What does one support represent in a grid?
Each pair of length-axis and width-axis marks represents one support location.
What do the layout marks refer to?
Use the stated origin, centerline or face reference, and units shown with the result. Display rounding may differ from the internal coordinates.
Does this approve the selected dimensions or product?
No. It lays out the dimensions you enter and does not establish structural capacity, product cutting permission, or installation compliance.
Additional examples and limits
Outside outline to support centers
For a 16 × 12-ft outside outline, 2.5-in single bearers, 4-in inner/outer bearer set-ins and entered 3-ft maximum bearer centers: the across-deck center span is 144 − 4 − 4 − 2.5 = 133.5 in. Four equal intervals give five bearer lines. With 5.5-in supports, 4-in support end set-ins and entered 3-ft centers along each bearer: 192 − 2 × 4 − 5.5 = 178.5 in gives five intervals and six supports per line, or 30 supports.
The along-deck near faces start at 4 in, while the first support center is 6.75 in (0.5625 ft). Across the deck, the first bearer and support center is 5.25 in, so the first support near face is 2.5 in. Double bearers shift the centerlines but keep five support rows and 30 supports in this example. Omitting the wall-side row for an entered 1.5-in ledger gives four rows and 24 supports; the ledger center and free-bearer centers use their respective actual widths.
Two supports or rows that would overlap are rejected. A width or set-in leaving no positive center span is rejected. An exact 3-ft maximum does not add a support; exceeding it does. These are known-size arithmetic examples, not recommended structural dimensions, footing sizes, allowable spans or installation details.
Rectangular centerline set-out
For 16 × 12 ft and entered 4-ft maximum centers on both axes: length marks are 0, 4, 8, 12, 16 ft; width marks are 0, 4, 8, 12 ft. Every pair is one center, so 5 × 4 = 20 supports. For 10 × 7 ft with entered maxima of 4 ft along and 3 ft across, both axes have three equal intervals: 10/3 and 7/3 ft. Four marks on each axis give 16 centers.
A span shorter than its entered maximum still has two endpoint marks; a 0.5 × 0.25-ft rectangle therefore has four mathematical centers. These are layout examples, not approved structural dimensions. Marks refer to centers, not near-side measurements. Output marks retain calculation precision; verify measurement rounding before transfer. No ledger, offset, slope or structural sizing is inferred.