Deck support grid calculator

Deck / Layout

Count supports from known bearer lines, a centerline grid, or an outside deck outline with actual member widths and set-ins.

Enter your inputs

A worked project example is loaded and calculated automatically. Replace the values with your project inputs.

Choose the option that matches your project.
ft
Enter deck length in feet.
lines
Use a whole number.
ft
Enter support spacing in feet.
Limits and notes

Known-line mode counts supports along entered bearer lines. The centerline grid uses the entered boundary-center spans and includes both endpoints on each axis; neither path deducts actual member widths or set-ins. Outside-outline mode uses the overall deck dimensions and known actual widths. Supports are centered below the bearer centerlines, without housed/notched support offsets. Every pair of center-axis marks is one support.

In outside-outline mode, bearer set-ins run from a deck edge to the boundary bearer's outside face. Double bearers are two entered member thicknesses with no gap, still one support line. Support end set-in runs from each deck end to the nearest support face. Actual support width is a square width or round diameter, the same along both axes; it is not a footing size. Ledger mode uses its own thickness and omits the wall-side support row.

Center coordinates are in feet; near-side support-face marks are in inches from the same deck corner. Outside-outline lists display up to three decimals; verify practical measurement rounding before transfer. A negative near-side mark means that face extends beyond the deck outline; the point still marks its center. The schematic scales axes independently and is not a construction plan. No member sizing, support height, housed/notched placement, slope, foundation design or structural approval is inferred. The 1,000-point display limit is a UI bound.

About this calculator

For known bearer lines, the grid multiplies their count by the support positions required along each line at the entered spacing.

Steps

  1. Support input

    Choose the option that matches your project.

  2. Deck length

    Enter deck length in feet.

  3. Bearer lines

    Use a whole number.

  4. Support spacing

    Enter support spacing in feet.

  5. Deck width (available in another mode)

    Enter deck width in feet.

  6. Maximum cross-deck spacing (available in another mode)

    Enter maximum cross-deck spacing in feet.

  7. Actual member thickness (available in another mode)

    Enter actual member thickness in inches.

  8. Inner set-in (available in another mode)

    Enter inner set-in in inches.

  9. Outer set-in (available in another mode)

    Enter outer set-in in inches.

  10. Maximum bearer centers (available in another mode)

    Enter maximum bearer centers in feet.

  11. Bearer members (available in another mode)

    Choose the option that matches your project.

  12. Bearing boundary (available in another mode)

    Choose the option that matches your project.

  13. Actual ledger thickness (available in another mode)

    Enter actual ledger thickness in inches.

  14. Actual support width (available in another mode)

    Enter actual support width in inches.

  15. Support end set-in (available in another mode)

    Enter support end set-in in inches.

  16. Support centers along bearer (available in another mode)

    Enter support centers along bearer in feet.

Formula

known lines: bearers × (ceil(length ÷ support spacing) + 1). Centerline grid: equally divided maximum-spacing intervals on both axes. Outside outline (convert deck ft to in first): length center span in inches = deck length in inches − 2 × support set-in in inches − support width in inches; cross-deck centers use actual widths and set-ins in inches. Every pair of center marks is one support.

Notation: ceil rounds up to the next whole number.

Interpret the result

Each crossing of a bearer line and a support mark is counted once. The grid is a geometric takeoff, not foundation sizing.

Worked example

Three bearer lines with 16-ft runs and 4-ft maximum spacing use ceil(16 ÷ 4) + 1 = 5 supports each. 3 × 5 = 15 supports.

Example result: 15 supports

Example inputs
Support input
Known bearer line count
Deck length
16 ft
Bearer lines
3 lines
Support spacing
4 ft

FAQs

What does one support represent in a grid?

Each pair of length-axis and width-axis marks represents one support location.

What do the layout marks refer to?

Use the stated origin, centerline or face reference, and units shown with the result. Display rounding may differ from the internal coordinates.

Does this approve the selected dimensions or product?

No. It lays out the dimensions you enter and does not establish structural capacity, product cutting permission, or installation compliance.

Additional examples and limits

Outside outline to support centers

For a 16 × 12-ft outside outline, 2.5-in single bearers, 4-in inner/outer bearer set-ins and entered 3-ft maximum bearer centers: the across-deck center span is 144 − 4 − 4 − 2.5 = 133.5 in. Four equal intervals give five bearer lines. With 5.5-in supports, 4-in support end set-ins and entered 3-ft centers along each bearer: 192 − 2 × 4 − 5.5 = 178.5 in gives five intervals and six supports per line, or 30 supports.

The along-deck near faces start at 4 in, while the first support center is 6.75 in (0.5625 ft). Across the deck, the first bearer and support center is 5.25 in, so the first support near face is 2.5 in. Double bearers shift the centerlines but keep five support rows and 30 supports in this example. Omitting the wall-side row for an entered 1.5-in ledger gives four rows and 24 supports; the ledger center and free-bearer centers use their respective actual widths.

Two supports or rows that would overlap are rejected. A width or set-in leaving no positive center span is rejected. An exact 3-ft maximum does not add a support; exceeding it does. These are known-size arithmetic examples, not recommended structural dimensions, footing sizes, allowable spans or installation details.

Rectangular centerline set-out

For 16 × 12 ft and entered 4-ft maximum centers on both axes: length marks are 0, 4, 8, 12, 16 ft; width marks are 0, 4, 8, 12 ft. Every pair is one center, so 5 × 4 = 20 supports. For 10 × 7 ft with entered maxima of 4 ft along and 3 ft across, both axes have three equal intervals: 10/3 and 7/3 ft. Four marks on each axis give 16 centers.

A span shorter than its entered maximum still has two endpoint marks; a 0.5 × 0.25-ft rectangle therefore has four mathematical centers. These are layout examples, not approved structural dimensions. Marks refer to centers, not near-side measurements. Output marks retain calculation precision; verify measurement rounding before transfer. No ledger, offset, slope or structural sizing is inferred.